Hi All, I am at wits and and I have already replaced most parts of my system. I am not producing chlorine unless I manually (at the box) press and hold in the button to put in boost mode, then I am producing 100% chlorine. In the past month I have replaced the SWG cell, the sensor and the...

Jandy error codes. Things To Know About Jandy error codes.

FAULTLOW. WATER FLOW. Verify circulating pump is on and all necessary valves are in the correct positions. Verify filter and skimmers are clean. Check water level in pool. Temporarily turn off all fountains and water falls that bypass the heat pump water inlet. If this does not correct the problem, call for service.As a pool owner, encountering error codes on your Jandy AquaPure system can be a frustrating experience. These error codes are designed to help you understand Jandy JXi 400 Pdf User Manuals. View online or download Jandy JXi 400 Installation And Operation Manual ... Ignition Control LED Service Codes. 38. Section 11 ... codes are more common than level 2 codes and can typically be troubleshooted by the homeowner and a Jandy technical representative. Although you can troubleshoot and determine the issue yourself, we do not recommend that you replace any internal parts if you do not feel comfortable.If you DO purchase a new cell, you will maximize life by buying the largest cell that will work with that power supply. It looks like that might be the PLC1400, which lists for $919.17 in the 2011 Zodiac catalog. Currently, Amazon lists a JANDY PLC1400 Pure Link Replacement Cell Kit 1400 for about $625. PoolDoc / Ben.

12Code 172& 181appearyesCheck salinity flowsensor for damage,or impropermounting.Conduct self testof the front boardto ensure the flowsensor …

4. Posted July 24, 2010. Hi. I am getting codes 194 & 125 and the unit is not producing chlorine. I have cleaned the cell (was scaled on each end) and re-instlled but again the codes have come back on. The flow sensor is clean. The temperature sensor matches the pool temp. Does anyone have any ides what to do next. Quote.Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts.

beachman. i have a three year old Aquapure 1400, cell reversing light steady - non operational with a 170 service code. 170 comes up as either a incoming voltage issue or a front board issue. I rewired the system completely recently adding in a heavy duty Intermatic pool timer, and it worked for two weeks fine, but after adding in a GFI outlet ...Level 1 service key are more common longer level 2 codes and canister typically be troubleshooted by the homeowner and a Jandy technical representative. Even her can troubleshoot and determine to issue yourself, we does not recommend which you replace random intra parts if you do no feel comfortable.Onboard diagnostics or OBD/OBD-II codes are those dreaded engine error codes that only trained auto mechanics seem to understand. Take a few minutes to gain a greater understanding...I have codes 171 and 183. Cleaned the cell as well as the flow sensor and still have the service light on and low chlorine level in the pool. Any thoughts before i start replacing parts. We have tried acid cleaning the cell as well as lightly sanded the sensor. Still not working. Since our...Install the pump as close to the pool or spa as possible. To reduce friction loss and improve eficiency, use short, direct suction piping returns. Install a minimum of 5 feet (1.5 meters) from the inside wall of the pool and spa. Canadian installations require a minimum of 9.8 feet (3 meters) from pool water level.

Low cell current in forward direction - check DC cord, clean cell if necessary or replace cell. 121. Low cell current in reverse direction, same as 120 above. 123. Low to no current at cell - check DC cord, clean cell or replace if necessary. 124. High current indicated at the cell - this usually means a bad PIB. 125.

(Generates 173 - Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present)Contact a pool professional.188VAC input voltage is too low. (Generates 173 code if Level II code 187 is present)Contact a pool professional.189Relay not conducting in the forward direction.

Laars & Jandy Products. Ω at 20 K or above. Thermistor Test Chart. Temp Resistance Temp Resistance. 50 ° F 19.898 K Ohms 78 ° F 9.735 K Ohms. 51 ° F 19.435 K Ohms 79 ° F 9.483 K Ohms. 52 ° F 18.871 K Ohms 80 ° F 9.284 K Ohms. 53 ° F 18.382 K Ohms 81 ° F 9.079 K Ohms. 54 ° F 17.902 K Ohms 82 ° F 8.864 K Ohms. 55 ° F 17.473 K Ohms 83 ...Do not confuse this for not lighting and turn it off. Also, if heater hasn't been used in awhile, the heater will stop trying to ignite after three tries. You will need to turn it off, then on again to reset it. The symptom you are describing could be a flame sensor too. It will light, then shut right off. If there is no continuity, unplug all the Jandy Valve Actuators (JVAs), replace the fuse (3.15 amp), and turn on the power. If the fuse blows with all JVAs unplugged, the circuit board is damaged and needs to be replaced. Those are all sensor codes. More than likely your sensor has failed. If it is also telling you salt is low, do not put any salt in until you either replace the sensor, or have the water tested at the pool store (no test strips). Jandy JXI series gas pool heater - FAULT CHECK IGN STEPS explained in this Step-by-Step Instructional Video.Inspection Camera: https://amzn.to/3prttIRLet's M... The 170 code is usually caused by low AC voltage from back board. This could be an issue with the board/transformer however what I have found MANY times is that code 170 is caused by the trisensor, you won't find that information in a troubleshooting guide, comes more from experience, if you have a multimeter you can verify voltage from transformer, board, etc. but I recommend as a start to ...Removed the cover and set it aside with power disconnected at the breaker. Carefully check to be sure no wires came loose and reconnect if they did. Reset breaker and allow the RS 12 to power up. Start the heater at it's control panel.

Ok Mary, this is what Jandy told me: You should have a separate control screen for the Aqua pure. if you lok on that screen ,there should be a fault code. We need that code to know how to procede further. Ask Your Own Pool and Spa Question. Pool and Spa Expert: ... Jandy JXi 400 Pdf User Manuals. View online or download Jandy JXi 400 Installation And Operation Manual ... Ignition Control LED Service Codes. 38. Section 11 ... Fault Codes. A fault code indicates a specific issue or condition that will require action before the equipment can resume operating. Please perform the following troubleshooting. If the issue reoccurs, please see "Contacting AquaCal AutoPilot, Inc." on page 1.Jandy AquaLink ® Automation Systems *Based on October 2022 list price comparisons of 1.85 HP variable-speed pumps from the 3 leading U.S.-based pool pump manufacturers. **Based on a 22,500 gallon pool with two turnovers per day at an energy cost of $0.195/kWh vs. comparable single speed pumps; when tested in accordance with the applicable ...Jandy LXi heater optional control can be installed remotely with 22AWG 4 conductor wire up to 300'. The additional control (p/n R3008800) can also be wired for control in the pool house or in the home. All wiring must be done in accordance with applicable local and National codes and requirements.The Jandy Aquapure PLC1400 stands as the pinnacle of pool sanitation systems, boasting cutting-edge technology and unparalleled efficiency. Engineered for pools ranging from 12,000 to 40,000 gallons, this system redefines ease of use and reliability in maintaining water purity. Advanced Cell Technology: Equipped with a 3-port cell kit, this ...

Follow these steps to test the sensor: Step 1: Turn off the power to the heater. Step 2: Locate the thermostat sensor near the heater's inlet and outlet pipes. Step 3: Disconnect the sensor from the control panel. Once you have completed these steps, use a multimeter to check the resistance of the sensor.Getting service codes 125 & 194 on a Aqua Pure 1400. Cleaned the cell, still got the codes. Ran through the trouble shooting guide and reviewed the numbers over the phone with one of the Jandy techs.

Sn3 = Temp sensor malfunction. SnA = Spa is shut down. Sensor plugged into jack A is not working. Snb = Spa is shut down. Sensor plugged into jack B is not working. SnS = Sensors out of balance. If alternating with temp, may be temporary condition. If display shows only this message (blinking) spa is shut down.Dougiel1 May 31, 2021, 1:06pm 1. I have a Jandy aquapure plc700 with error codes flashing on my display panel. With your website's help, I was able to determine what may the the issues but there is one code I still cannot determine. What does the Jb or J6 error mean?JANDY JXI POOL HEATER FAULT CODE - NEED HELP - TROUBLE FREE POOL. 2022-05-16 Start with the circuit breaker the heater is attached to. Check that it is not tripped and reset it. Post pics of your equipment pad and all your pool controls. see pics - it appears the pool pump is powered through the breaker panel then out of the pool pump runs ...Page 45: Service Codes Page 45 Nature Fusion Soft Installation and Operation Manual 2® Service Codes Code Number Possible Cause Corrective Action Low current in forward direction to cell. 1. Clean cell if necessary (see Section 6.5). 2. Check DC Cord. Low current in reverse direction to cell. 1. Page 46: Level 2 Service CodesObject moved to here.It's not a testimonial on methods bad the power is,( Jandy your a great manufacturer), but more how related, here I include myself, we ca be at product manuals and documents. Who actually reads these, anyway? So, where mistake code is respective Jandy unity displaying? LEVEL 1 MAINTENANCE CODES4. Posted July 24, 2010. Hi. I am getting codes 194 & 125 and the unit is not producing chlorine. I have cleaned the cell (was scaled on each end) and re-instlled but again the codes have come back on. The flow sensor is clean. The temperature sensor matches the pool temp. Does anyone have any ides what to do next. Quote.May 28, 2022 · I have a Jandy JXI260N heater, that will not start. It has a Fault High Flue Temp message as soon as it boots. I have jumped out the flue temp sensor with a wire, thinking it will either be open or closed depending on the sensor temperature. It does not have a fusable link in the flue. It is part R0719400. 2 wires come out of it. Backyard Paradise Luxury Pools. Founded in 2015, Backyard Paradise Luxury Pools have established themselves as one of the leading designers and builders of high-end custom pools.Yeah. Answered in 1 day by: HVAC Technician: JordanB714. Inspect the flu for obstructions and confirm damper is opening if one is installed. If those things are good replace the flu temp semsor. Ask Your Own HVAC Question. Sensor. 105 Satisfied Customers.

beachman. i have a three year old Aquapure 1400, cell reversing light steady - non operational with a 170 service code. 170 comes up as either a incoming voltage issue or a front board issue. I rewired the system completely recently adding in a heavy duty Intermatic pool timer, and it worked for two weeks fine, but after adding in a GFI outlet ...

From https://www.justanswer.com/ythiJustAnswer Customer from Granbury, TX: versaflo fault on a newly installed Jandy pool heaterPearl Wilson: Assistant: Who ...

Jandy aquapure 1400 on sale: best price on zodiac jandy aquapure plc Jandy aquapure cell 1400 aqua pure kit inyopools larger gallon port Jandy aqua pure 1400 3-port cell, 40,000 gallon (o.e.m) Jandy Aqua Pure 1400 3-port cell, 40,000 Gallon (O.E.M) - PLC1400Gold Supporter. Sep 4, 2017. 26. Edgewater MD. Jul 12, 2018. #1. Troubleshooting my lack of chlorine and my SWCG is showing a code 123 (low or no current to cell). I checked the cable (new last year) and there is corrosion on the two outside posts and inside the terminals.The Jandy Aquapure PLC1400 stands as the pinnacle of pool sanitation systems, boasting cutting-edge technology and unparalleled efficiency. Engineered for pools ranging from 12,000 to 40,000 gallons, this system redefines ease of use and reliability in maintaining water purity. Advanced Cell Technology: Equipped with a 3-port cell kit, this ...Jandy LXi Pool and Spa/Hot Tub Heater. Jandy LXi pool and spa/hot tub heaters exceed environmental standards for Low NOx emissions. Lower emissions mean you can enjoy your pool or spa/hot tub with confidence, knowing your pool equipment is designed with the environment in mind. The Jandy Pro Series LXi comes automation-ready for easy ...Match case Limit results 1 per page. Click here to load reader. date post. 13-Mar-2018; Category. Documents; view. 213; downloadYou need to take your readings with the cell connected and cell on (under load). Pull the plug on the cell as if you were unplugging it, but not completely, just enough to where you can get your test probes in there. A 120 code indicates cell service (check, clean, or replace).If If Black wire Black wire is is OK OK replace replace GUI GUI. 1. Check Check Black Black wire wire connections to Pressure Switch. connections to Pressure Switch. 2. Do Do continuity continuity test test on on Black Black wire. wire. Black wire. 3.Hello Jandy Answer Man, I have a PLC 1400 AquaPure and it is generating fault codes 189 and 171 (And chlorine is hardly being generated)--and salt content is 3.8ppm .... Can this be fixed or do I need …Our Jandy APURE1400 has the service light on and error codes of 182 and 175. We cleaned the cell censor with water - Answered by a verified Pool and Spa Expert

I called Jandy/Zodiac tech support and they walked me thru testing the power board. I was only getting erratic power readings to the ignitor, anywhere from 36-75V. Tech support said my next step is to replace the High Voltage assembly, so I have one ordered and will give this another crack when the part arrives.Jandy LRZ pool heater not heating pool - Ignition failure. Bad gas valve replaced. Yes Maam, the part is on the truck!Merchandise Requests (United States Onl...H2O Sensor Failure | How To Fix | Jandy JE Series Heat Pumps | Chlorine KingIn this video I show you how to replace a failed H2O sensor specifically in a Jan...Jun 23, 2012 · Toward the end of last season my Jandy/Aquapure Unit started with error code 123. It was 5 years old then. After 2 cleanings of the salt cell with acid... Instagram:https://instagram. jeep wrangler limp mode resetlaparoscopic lysis of adhesions cpt codeis uta free right nowbracketology simulation My Jandy is saying General Fault. Actually... Aquapure at 15%, SALT at 2900PPM, check aquapure, General fault, - Answered by a verified Pool and Spa Expert. We use cookies to give you the best possible experience on our website. ... jandy aquapure 1400 code 170 service on the panel today. racetrac vero beachexpert grill griddle replacement Press and hold the test buttons marked salinity and R-temp. While still pressing the test buttons press the ‘Salinity’ key (‘C’) on the front cover of the unit. The LCD should read …I just replaced my Jandy AquaPure 1400 Chlorination unit. The new unit is connected to 240 volts (voltage is good, I checked that). I am getting a service code alarm - code 170 that says " Possible Fr … read more punta gorda bridge accident today 6700 REV C on Jandy Remote RS4 RS6 RS8 or Power Center? This blog by FixYourBoard.com to help troubleshoot your Jandy/Blue Haven pool system.Hello , This thread has been inactive for over 60 days. New postings here are unlikely to be seen or responded to by other members. For better visibility, consider Starting A New Thread.